<?xml version="1.0" encoding="utf-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en-GB">
  <title>Punit Govind: Cisco home lab and infrastructure expertise</title>
  <subtitle>An independent technical site by Punit Govind, an infrastructure and network architect: a three site Cisco home lab, and pages on networks, security, data centres, cloud, industries, governance and service, with diagrams you can step through.</subtitle>
  <link href="https://punit.co.uk/feed.xml" rel="self" type="application/atom+xml"/>
  <link href="https://punit.co.uk/" rel="alternate" type="text/html"/>
  <id>https://punit.co.uk/</id>
  <updated>2026-11-28T09:00:00Z</updated>
  <author><name>Punit Govind</name><uri>https://punit.co.uk/</uri></author>
  <icon>https://punit.co.uk/images/favicon-96.png</icon>
  <entry>
    <title>Hyperscale Pods Reference Architecture</title>
    <link href="https://punit.co.uk/hyperscale-pods/"/>
    <id>https://punit.co.uk/hyperscale-pods/</id>
    <published>2026-03-03T09:00:00Z</published>
    <updated>2026-11-28T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>A hyperscale pod architecture builds a large estate from pods: repeatable units of racks, network, storage, management and power, built in a factory, run as one unit and retired whole. Each pod belongs to a family, such as general compute, containers or AI, and every family uses the same kinds of block. A service&#x27;s tier decides how many pods, halls and sites it spans, and every layer, from facilities to operations, carries out the same pattern.</summary>
  </entry>
  <entry>
    <title>AI Infrastructure: GPU Clusters and Data Centres</title>
    <link href="https://punit.co.uk/ai-infrastructure/"/>
    <id>https://punit.co.uk/ai-infrastructure/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-20T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>A GPU cluster needs four separate networks, so storage bursts and user traffic never slow a training run: a compute back end, a front end, a storage network and out of band management. The back end is rail optimised and non blocking, with one NIC (network interface card) per GPU. It runs on InfiniBand, or on Ethernet tuned to slow senders before anything drops, because a training step waits for its slowest flow.</summary>
  </entry>
  <entry>
    <title>Networking Fundamentals: OSI, TCP/IP and Packets</title>
    <link href="https://punit.co.uk/networking-fundamentals/"/>
    <id>https://punit.co.uk/networking-fundamentals/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>A host sends a packet for another subnet to its default gateway, using ARP (Address Resolution Protocol) to find the gateway&#x27;s MAC (media access control) address. Each router then picks the longest matching route, lowers the TTL (time to live) by one and builds a fresh frame for the next hop. MAC addresses change at every routed hop. IP addresses and ports stay the same end to end, unless NAT (network address translation) or a proxy rewrites them.</summary>
  </entry>
  <entry>
    <title>Copper Cabling: Cat5e to Cat8, RJ45 and PoE</title>
    <link href="https://punit.co.uk/copper-cabling/"/>
    <id>https://punit.co.uk/copper-cabling/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>A new building should use Cat6A, tested to 500 MHz, because it carries 10GBASE-T over the full 100 m channel and runs cooler with high power PoE (Power over Ethernet). That channel is up to 90 m of installed permanent link plus no more than 10 m of cords. Cat6 carries 10GBASE-T dependably only to 37 m, and Cat7 and Cat8 add nothing for office LAN cabling. Every link should be certified with a field tester before handover.</summary>
  </entry>
  <entry>
    <title>Fibre Optics: Types, Connectors and Loss Budgets</title>
    <link href="https://punit.co.uk/fibre-optics/"/>
    <id>https://punit.co.uk/fibre-optics/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>Single mode fibre has a 9 µm core that carries one path of light, so its reach is set by the optic, from 500 m to tens of kilometres. Multimode fibre has a 50 or 62.5 µm core that carries many paths, which spread each pulse and limit reach, such as 100 m for 100G on OM4. Multimode uses cheap 850 nm VCSEL (vertical cavity surface emitting laser) optics. I fit OS2 single mode between buildings and for most new links above 100G.</summary>
  </entry>
  <entry>
    <title>IP Addressing and Subnetting: Masks, CIDR, IPv6</title>
    <link href="https://punit.co.uk/ip-addressing/"/>
    <id>https://punit.co.uk/ip-addressing/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>Find the octet where the mask is neither 255 nor 0, and take that value from 256 to get the block size. The network address is the multiple of the block at or below the address, and the broadcast is one less than the next block. For 10.20.30.77/27 the block is 32, so the network is 10.20.30.64, the broadcast is 10.20.30.95, and the 30 usable hosts run from .65 to .94.</summary>
  </entry>
  <entry>
    <title>Switching and Campus LAN: VLANs, STP, EtherChannel</title>
    <link href="https://punit.co.uk/switching/"/>
    <id>https://punit.co.uk/switching/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>STP (Spanning Tree Protocol) elects one root switch, works out the lowest cost path to it from every other switch, and blocks just enough ports to break every loop. If a link fails, a blocked port takes over. Loops matter because an Ethernet frame has no time to live, so a broadcast in a Layer 2 loop circles until the loop is broken. RSTP (Rapid Spanning Tree Protocol) converges in about a second, against 30 to 50 seconds for classic STP.</summary>
  </entry>
  <entry>
    <title>Routing Protocols: OSPF, EIGRP and BGP Explained</title>
    <link href="https://punit.co.uk/routing/"/>
    <id>https://punit.co.uk/routing/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>A router compares the destination address with its routing table and uses the longest matching prefix. If two routing sources offer exactly the same prefix, it trusts the one with the lower administrative distance. If one protocol offers several paths, the lowest metric wins and equal paths share the load. OSPF (Open Shortest Path First), EIGRP (Enhanced Interior Gateway Routing Protocol) and BGP (Border Gateway Protocol) each fill that table in their own way.</summary>
  </entry>
  <entry>
    <title>Security Fundamentals: Encryption, PKI and IPsec</title>
    <link href="https://punit.co.uk/security-fundamentals/"/>
    <id>https://punit.co.uk/security-fundamentals/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>Network security protects confidentiality, integrity and availability, often called the CIA (confidentiality, integrity and availability) triad. AAA (authentication, authorisation and accounting) sends every login to a central server. Symmetric encryption such as AES (Advanced Encryption Standard) carries the data, while asymmetric keys and Diffie-Hellman agree the keys. Certificates from a PKI (public key infrastructure) prove who is on the other end. TLS (Transport Layer Security) and IPsec (Internet Protocol security) tunnels combine these blocks, and switch features guard each access port.</summary>
  </entry>
  <entry>
    <title>Network Troubleshooting: Method, Tools and Faults</title>
    <link href="https://punit.co.uk/troubleshooting/"/>
    <id>https://punit.co.uk/troubleshooting/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>A network fault is best found with the same loop every time: define the problem and its scope, gather facts with read only commands, check what changed, then test one hypothesis at a time. The fix goes through change control and is verified against the pre checks. The OSI (Open Systems Interconnection) model gives a map of seven layers, and the symptom decides where to start. A root cause must explain what fails and what still works.</summary>
  </entry>
  <entry>
    <title>Network Support and Service Management: ITIL</title>
    <link href="https://punit.co.uk/service-management/"/>
    <id>https://punit.co.uk/service-management/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>ITIL (the IT Infrastructure Library) gives network support a common set of practices. Incident management restores service as fast as possible, even with a workaround. Problem management then finds and removes the root cause, so the incident stops coming back. Change enablement lets safe changes flow and gives risky ones scrutiny, because uncontrolled change causes more outages than hardware does. Monitoring, patching and end of life planning keep every device healthy and supported.</summary>
  </entry>
  <entry>
    <title>Glossary of Network and Infrastructure Terms</title>
    <link href="https://punit.co.uk/glossary/"/>
    <id>https://punit.co.uk/glossary/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Foundations"/>
    <summary>This glossary spells out more than 1,400 acronyms and terms used across networking, data centres, cloud, security, audio visual work and regulation. Each entry gives what the letters stand for and one plain line on what the term does. Most entries also link to the page on this site where I explain the term in full, with diagrams.</summary>
  </entry>
  <entry>
    <title>SD-WAN and Software Defined Networking</title>
    <link href="https://punit.co.uk/sd-wan/"/>
    <id>https://punit.co.uk/sd-wan/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>Cisco&#x27;s software defined WAN splits the network into orchestration, management, control and data planes. The Validator authenticates each new edge, the Manager pushes its template, and the Controllers exchange routes with the edges using OMP (Overlay Management Protocol), acting like route reflectors. Edges build IPsec tunnels directly to each other over every transport and measure each one with BFD (Bidirectional Forwarding Detection). Each application then takes the path that meets its service level.</summary>
  </entry>
  <entry>
    <title>WAN, MPLS and VPN Design and Troubleshooting</title>
    <link href="https://punit.co.uk/wan-and-vpn/"/>
    <id>https://punit.co.uk/wan-and-vpn/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>Sites are joined over circuits such as leased lines, broadband, 4G and 5G, carrier Ethernet or a carrier&#x27;s MPLS (Multiprotocol Label Switching) Layer 3 VPN. MPLS keeps customers apart with labels and VRF (virtual routing and forwarding) tables, but it is private, not encrypted. Over untrusted paths, IPsec (Internet Protocol Security) tunnels encrypt traffic, and DMVPN (Dynamic Multipoint VPN) lets one hub serve every spoke. Failover follows real reachability, through probes or BGP (Border Gateway Protocol) with BFD (Bidirectional Forwarding Detection).</summary>
  </entry>
  <entry>
    <title>SD-Access Campus Fabric: LISP, VXLAN and TrustSec</title>
    <link href="https://punit.co.uk/campus-fabric/"/>
    <id>https://punit.co.uk/campus-fabric/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>Cisco&#x27;s campus fabric splits the network into four planes. The underlay is a plain routed network running IS-IS (Intermediate System to Intermediate System). LISP (Locator/ID Separation Protocol) keeps a live directory of which switch every endpoint sits behind, and VXLAN (virtual extensible LAN) carries traffic between switch loopbacks. Cisco ISE (Identity Services Engine) gives each user or device a scalable group tag (SGT), and policy is enforced by group pair, not by IP address.</summary>
  </entry>
  <entry>
    <title>Wireless and Mobile Networks: Wi-Fi, WPA3, 5G</title>
    <link href="https://punit.co.uk/wireless/"/>
    <id>https://punit.co.uk/wireless/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>A reliable enterprise Wi-Fi network is designed for airtime, not just coverage, starting from the weakest client it must serve. Radio is shared and half duplex, so one slow, distant client can use more airtime than ten fast ones. I design each area to a target, such as −67 dBm and 25 dB SNR (signal to noise ratio) for voice, then prove it with a survey. Identity through 802.1X decides each user&#x27;s segment, and WPA3 (Wi-Fi Protected Access 3) secures the link.</summary>
  </entry>
  <entry>
    <title>QoS and Traffic Shaping Design and Troubleshooting</title>
    <link href="https://punit.co.uk/qos-and-traffic-shaping/"/>
    <id>https://punit.co.uk/qos-and-traffic-shaping/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>QoS (quality of service) decides which traffic goes first, which gets a reserved share and which is dropped when a link is congested. It never adds bandwidth and only acts when a queue forms. Traffic is marked near the source with a DSCP (Differentiated Services Code Point) value, and voice goes into a policed strict priority queue. Where a carrier polices below the port speed, a shaper at the contracted rate moves the congestion into the customer&#x27;s own router.</summary>
  </entry>
  <entry>
    <title>Cisco IOS, IOS XE and Catalyst Platforms</title>
    <link href="https://punit.co.uk/cisco-ios-and-catalyst/"/>
    <id>https://punit.co.uk/cisco-ios-and-catalyst/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>Classic Cisco IOS (Internetwork Operating System) is one image in which every task shares one memory space, so one faulty task can reload the whole device. IOS XE runs IOS as one process, IOSd (the IOS daemon), on a Linux kernel, so a fault in one process need not take the device down. The command line looks the same. IOS XE runs current Catalyst 9000 switches and Catalyst 8000 routers, and upgrades in install mode with a rollback timer.</summary>
  </entry>
  <entry>
    <title>Arista EOS and Juniper Junos, Compared With Cisco</title>
    <link href="https://punit.co.uk/arista-and-juniper/"/>
    <id>https://punit.co.uk/arista-and-juniper/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>Arista EOS (Extensible Operating System) looks like Cisco IOS (Internetwork Operating System) at the prompt, but runs each feature as a separate agent on Linux, sharing state through a database called Sysdb. A failed agent restarts without a reload. Juniper Junos changes nothing until a commit, and keeps the last 50 commits for rollback. Its routing policy is built from policy statements, not route maps. Between vendors, I use only standard protocols such as BGP (Border Gateway Protocol) and OSPF (Open Shortest Path First).</summary>
  </entry>
  <entry>
    <title>Network Security and Zero Trust Design</title>
    <link href="https://punit.co.uk/security/"/>
    <id>https://punit.co.uk/security/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>Zero trust means no network location earns trust. Guidance from NIST (the US National Institute of Standards and Technology) says every request is checked per session, using identity, device health and policy, with least privilege. In a network that becomes zones with a firewall between them, micro segments around each workload, and access control so every device proves who it is. Remote users are connected to one application, not to the whole network.</summary>
  </entry>
  <entry>
    <title>Firewall Platforms: ASA, Palo Alto, FortiGate, SRX</title>
    <link href="https://punit.co.uk/firewalls/"/>
    <id>https://punit.co.uk/firewalls/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>A stateful firewall sends the first packet of each flow through the slow path. That means a session lookup, a route lookup to find the destination zone, the rules read top down with the first match winning, then NAT (network address translation). It writes a session holding both the original and translated addresses. Every later packet, including the reply, matches that session and takes the fast path with no rule lookup. Vendors differ mainly in where NAT sits against the policy check.</summary>
  </entry>
  <entry>
    <title>Load Balancing and Application Delivery on F5</title>
    <link href="https://punit.co.uk/application-delivery/"/>
    <id>https://punit.co.uk/application-delivery/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>A load balancer gives an application one stable address, the VIP (virtual IP address), and spreads new connections across a pool of servers. A health monitor removes any server that fails its checks, and a method such as round robin or least connections picks the next one. Persistence keeps a user on the same server when the application holds state. At Layer 7 the load balancer can end TLS (Transport Layer Security), route by URL, insert cookies and run a WAF (web application firewall).</summary>
  </entry>
  <entry>
    <title>Network Automation: Python, Ansible and APIs</title>
    <link href="https://punit.co.uk/automation/"/>
    <id>https://punit.co.uk/automation/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Networks and security"/>
    <summary>Safe network automation puts intent in a source of truth, such as NetBox, and in Git, then sends every change through a tested pipeline. Templates turn the data into configuration. Automated checks and a model of the network test it, people approve what checks cannot judge, and checks before and after prove the result. If the proof fails, the change rolls back on its own. Only the pipeline pushes to devices, apart from a recorded break glass change.</summary>
  </entry>
  <entry>
    <title>Data Centre Networks: Leaf and Spine Design</title>
    <link href="https://punit.co.uk/data-centre/"/>
    <id>https://punit.co.uk/data-centre/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>A leaf and spine network connects every leaf switch to every spine switch, so any two racks are two hops apart and every link carries traffic through equal cost routing. It replaced the three tier design because most data centre traffic now flows between servers, not out to users. The underlay is routed, with no spanning tree inside the fabric, and VXLAN (Virtual Extensible LAN) with EVPN (Ethernet VPN) carries the tenants. A leaf adds ports and a spine adds bandwidth.</summary>
  </entry>
  <entry>
    <title>VXLAN EVPN and Cisco ACI Data Centre Fabrics</title>
    <link href="https://punit.co.uk/data-centre-fabrics/"/>
    <id>https://punit.co.uk/data-centre-fabrics/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>VXLAN (Virtual Extensible LAN) wraps each Ethernet frame in UDP (User Datagram Protocol) and IP, so a routed fabric can carry tenant segments between leaf switches. EVPN (Ethernet VPN) is the control plane. It uses BGP (Border Gateway Protocol) to tell every leaf where each host&#x27;s MAC (media access control) and IP addresses live before traffic needs them. Every leaf is the gateway for its own subnets, and the spines route only the outer header.</summary>
  </entry>
  <entry>
    <title>Data Centre and Switch Cabling: DAC to MPO</title>
    <link href="https://punit.co.uk/data-centre-cabling/"/>
    <id>https://punit.co.uk/data-centre-cabling/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>Inside a rack, a passive DAC (direct attach copper) cable is the cheapest and coolest choice, but at 400G it stops at about 3 m. An AEC (active electrical cable) adds a retimer chip to reach about 7 m at 800G, and an AOC (active optical cable) reaches tens of metres. Once a link leaves the row or passes through patch panels, pluggable optics and structured fibre are the only option. All four plug into the same switch port cage.</summary>
  </entry>
  <entry>
    <title>Cisco Nexus and NX-OS Design and Operations</title>
    <link href="https://punit.co.uk/nexus-and-nx-os/"/>
    <id>https://punit.co.uk/nexus-and-nx-os/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>NX-OS (Nexus Operating System) is the Cisco operating system for Nexus data centre switches, and it is built to keep forwarding. It runs on a Linux kernel, and each feature runs as its own process with protected memory, started only when enabled. Unlike classic IOS (Internetwork Operating System), a crashed process restarts and reloads its saved state while the switch keeps forwarding. Checkpoints roll changes back, and supported switches can be upgraded while traffic flows.</summary>
  </entry>
  <entry>
    <title>VMware NSX Networking and the Distributed Firewall</title>
    <link href="https://punit.co.uk/vmware-nsx/"/>
    <id>https://punit.co.uk/vmware-nsx/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>VMware NSX moves switching, routing and a stateful firewall into the ESXi hypervisor kernel, so the physical network only carries IP between hosts. Overlay segments travel between host tunnel endpoints in Geneve (Generic Network Virtualization Encapsulation) over UDP (User Datagram Protocol) port 6081. Tier-0 gateways on Edge nodes connect to the physical switches, usually with BGP (Border Gateway Protocol), and the distributed firewall checks traffic at every virtual NIC (network interface card).</summary>
  </entry>
  <entry>
    <title>Data Centre Facilities: Power, Cooling, Racks</title>
    <link href="https://punit.co.uk/data-centre-facilities/"/>
    <id>https://punit.co.uk/data-centre-facilities/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>A data hall is planned from four numbers: the IT load in kW, its density per rack, the resilience it needs and how fast it will grow. Every rack gets an A and a B power feed on separate paths, each planned to run at no more than 40 percent. Cooling moves the same heat from the chip to the outside air. At 40 kW a rack air alone cannot carry the heat away, and rack scale AI systems need direct liquid cooling.</summary>
  </entry>
  <entry>
    <title>Servers, VMware vSphere and Windows Server</title>
    <link href="https://punit.co.uk/servers-and-virtualisation/"/>
    <id>https://punit.co.uk/servers-and-virtualisation/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>A resilient virtual server platform runs VM (virtual machine) workloads on a type 1 hypervisor, such as VMware vSphere, Microsoft Hyper-V or KVM (Kernel based Virtual Machine), across a cluster of balanced hosts. In vSphere, HA (high availability) restarts the VMs of a failed host, and admission control holds back capacity, usually N+1, so there is room to do it. DRS (Distributed Resource Scheduler) balances load with vMotion. Protected storage and redundant Active Directory, DNS and DHCP (Dynamic Host Configuration Protocol) services complete it.</summary>
  </entry>
  <entry>
    <title>Private Cloud, Storage and Data Protection</title>
    <link href="https://punit.co.uk/private-cloud/"/>
    <id>https://punit.co.uk/private-cloud/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>A private cloud is a stack of five layers on a data centre pod: facility, infrastructure, platforms, automation and workloads. Automation turns a virtualised data centre into a cloud, because teams order from a catalogue and code builds the same thing every time. The US NIST (National Institute of Standards and Technology) definition lists five traits: on demand self service, broad network access, pooled resources, rapid elasticity and measured use. Growth means adding another tested pod.</summary>
  </entry>
  <entry>
    <title>Cloud Architecture: AWS, Azure and Google Cloud</title>
    <link href="https://punit.co.uk/cloud/"/>
    <id>https://punit.co.uk/cloud/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>Cloud design starts with the shared responsibility model and a placement decision for each workload, so most estates end up hybrid. Every workload then lands in a landing zone: separate accounts, one identity source, a transit hub with a firewall, central logs and guardrails written as code. By default, production reaches on premises over two private connections in separate locations. Each service gets a recovery pattern matched to its agreed recovery objectives and its cost.</summary>
  </entry>
  <entry>
    <title>AWS, Azure and Google Cloud, Side by Side</title>
    <link href="https://punit.co.uk/cloud-platforms/"/>
    <id>https://punit.co.uk/cloud-platforms/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Data centre and cloud"/>
    <summary>AWS (Amazon Web Services), Azure and Google Cloud build networks from the same blocks under different names, with one big difference in scope. An AWS VPC (virtual private cloud) and an Azure VNet live in one region, while a Google Cloud VPC is global with regional subnets. AWS subnets sit in one Availability Zone, while Azure and Google Cloud subnets span zones. All three offer stateful security rules, outbound NAT (network address translation), private endpoints, transit hubs and private links to on premises.</summary>
  </entry>
  <entry>
    <title>Operational Technology and IT/OT Convergence</title>
    <link href="https://punit.co.uk/operational-technology/"/>
    <id>https://punit.co.uk/operational-technology/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Industries"/>
    <summary>OT (operational technology) connects safely to IT when control stays local and data leaves only through controlled paths. The Purdue model places each system in a level, with an industrial DMZ (demilitarised zone) at Level 3.5 between IT and OT. IEC (International Electrotechnical Commission) 62443 groups assets into zones joined by named conduits. Edge gateways read each machine once and publish outbound over MQTT (Message Queuing Telemetry Transport), so nothing connects into the controllers.</summary>
  </entry>
  <entry>
    <title>IoT and Edge: Devices, MQTT and Onboarding</title>
    <link href="https://punit.co.uk/iot-and-edge/"/>
    <id>https://punit.co.uk/iot-and-edge/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Industries"/>
    <summary>IoT devices are connected securely by giving each one its own identity, its own segment and only the flows it needs. Most sensors cannot do 802.1X, so the switch falls back to MAB (MAC authentication bypass) and a policy server profiles the device before placing it. Data travels as MQTT (Message Queuing Telemetry Transport) over TLS (transport layer security) on TCP (Transmission Control Protocol) port 8883. Gateways process data at the edge and keep the site working when the WAN is down.</summary>
  </entry>
  <entry>
    <title>Government and Defence Secure Architecture</title>
    <link href="https://punit.co.uk/government-and-defence/"/>
    <id>https://punit.co.uk/government-and-defence/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Industries"/>
    <summary>UK government systems are secured by following public guidance that ties controls to risk. The Cabinet Office Government Security Classifications Policy sets three tiers, OFFICIAL, SECRET and TOP SECRET, and the controls rise with each tier. The NCSC (National Cyber Security Centre) secure design principles start by mapping the whole system and assume something will still get through. Under Secure by Design, every service has senior risk owners, and evidence that the controls work is gathered throughout its life.</summary>
  </entry>
  <entry>
    <title>Low Latency Trading Networks and Market Data</title>
    <link href="https://punit.co.uk/low-latency-trading/"/>
    <id>https://punit.co.uk/low-latency-trading/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Industries"/>
    <summary>Trading networks cut latency by shortening every part of the path. Firms rent racks in colocation, in the venue&#x27;s own data hall, so the cable is a few tens of metres. Layer 1 switches copy market data to servers in a few nanoseconds, and kernel bypass or an FPGA (field programmable gate array) cuts the time inside each server. Between cities, distance dominates, so the route and the medium, such as microwave, matter more than any box.</summary>
  </entry>
  <entry>
    <title>Janet, eduroam and UK Education Networks</title>
    <link href="https://punit.co.uk/janet/"/>
    <id>https://punit.co.uk/janet/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Industries"/>
    <summary>Janet is the UK&#x27;s NREN (national research and education network), run by Jisc. It links universities, colleges and research institutes to each other, to research networks abroad through GÉANT, to cloud providers and to the internet, as one AS (autonomous system). A campus connects through an access link to a regional PoP (point of presence). Sites that cannot go offline use two links to two PoPs, with BGP (Border Gateway Protocol) and BFD (Bidirectional Forwarding Detection) for automatic failover.</summary>
  </entry>
  <entry>
    <title>Design Authority and Delivery Governance</title>
    <link href="https://punit.co.uk/design-authority/"/>
    <id>https://punit.co.uk/design-authority/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Governance and service"/>
    <summary>A technical design authority owns the technical design and decides what is approved. It does three jobs: it makes decisions, it sets standards, and it checks that what gets built matches what was agreed. Designs move forward through gates, each with a clear question, an owner and a written outcome. Each significant decision is written as an ADR (architecture decision record), and nothing goes live until operations accept the service.</summary>
  </entry>
  <entry>
    <title>Resilience, Risk and Cost in Infrastructure</title>
    <link href="https://punit.co.uk/resilience-and-cost/"/>
    <id>https://punit.co.uk/resilience-and-cost/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Governance and service"/>
    <summary>Availability is a business decision with a price. Each extra nine cuts the allowed downtime by ten: 99.9% allows 8.76 hours a year and 99.99% allows 52.6 minutes. Parts in a chain multiply, so the service is worse than any one part, and a redundant pair only helps if both halves cannot fail for the same reason. Each option should show its availability, recovery time and cost, including the cost of doing nothing.</summary>
  </entry>
  <entry>
    <title>TOGAF and Enterprise Architecture in Practice</title>
    <link href="https://punit.co.uk/togaf/"/>
    <id>https://punit.co.uk/togaf/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Governance and service"/>
    <summary>TOGAF (The Open Group Architecture Framework) is an open standard for EA (enterprise architecture): planning change across business, data, applications and technology so separate projects add up to one coherent estate. Its core is the ADM (Architecture Development Method), a cycle of a Preliminary phase and phases A to H around Requirements Management. Building blocks, principles, gap analysis and governance turn the method into designs, roadmaps and reviews. TOGAF expects to be tailored, and applied whole and unchanged it produces paperwork faster than decisions.</summary>
  </entry>
  <entry>
    <title>TM Forum Frameworks: eTOM, SID, ODA and Open APIs</title>
    <link href="https://punit.co.uk/tm-forum/"/>
    <id>https://punit.co.uk/tm-forum/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Governance and service"/>
    <summary>TM Forum frameworks give telecoms operators one vocabulary for OSS (operations support systems) and BSS (business support systems). The Business Process Framework (eTOM) names the work, the Information Framework (SID) names the things that work acts on, and the Functional Framework names the functions software must provide. ODA (Open Digital Architecture) turns those functions into components on a shared canvas. The components talk only through numbered Open APIs (application programming interfaces), such as TMF622 (Product Ordering Management).</summary>
  </entry>
  <entry>
    <title>ITIL 4 Service Management in Practice</title>
    <link href="https://punit.co.uk/itil/"/>
    <id>https://punit.co.uk/itil/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Governance and service"/>
    <summary>ITIL 4 is the 2019 edition of ITIL (originally the IT Infrastructure Library), a widely used body of guidance for running IT services. It describes a service value system that turns demand into value, shaped by seven guiding principles and four dimensions. Work flows through a value chain of six activities, using 34 practices. ITIL 4 replaced the five stage lifecycle and 26 processes of ITIL v3. ITIL Version 5, which PeopleCert began releasing in 2026, keeps the 34 practices.</summary>
  </entry>
  <entry>
    <title>PRINCE2 7 Project Delivery for Infrastructure</title>
    <link href="https://punit.co.uk/prince2/"/>
    <id>https://punit.co.uk/prince2/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Governance and service"/>
    <summary>PRINCE2 (Projects in Controlled Environments) keeps a project under control by naming who decides what, splitting the work into management stages and managing by exception. The project board commits to one stage at a time and checks the business case at every stage boundary. Each level works within agreed tolerances, and only a forecast breach goes up to the level above. The 7th edition, published in 2023, puts people at the centre and adds sustainability as a performance target.</summary>
  </entry>
  <entry>
    <title>1st, 2nd and 3rd Line IT Support Explained</title>
    <link href="https://punit.co.uk/it-support/"/>
    <id>https://punit.co.uk/it-support/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Governance and service"/>
    <summary>1st line is the service desk: the single point of contact that logs every contact, sets the priority and fixes what it can on the first contact using knowledge articles. 2nd line teams, such as deskside support and the NOC (network operations centre), hold admin rights and make standard changes. 3rd line are the engineers who design and build the platforms and lead root cause work. Line 0 is self service, and 4th line is the vendor or carrier.</summary>
  </entry>
  <entry>
    <title>End User Computing: Autopilot, Intune and Laptops</title>
    <link href="https://punit.co.uk/end-user-computing/"/>
    <id>https://punit.co.uk/end-user-computing/</id>
    <published>2026-10-24T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Governance and service"/>
    <summary>Windows Autopilot keeps the Windows build the supplier installed and adds the company layer from the cloud. The supplier registers each laptop&#x27;s hardware hash to the company, so at the welcome screen the device downloads the company profile. The user signs in with their work account and MFA (multi factor authentication). The laptop joins Microsoft Entra ID, enrols in Intune, and receives policy, certificates and apps over any internet connection, without anyone in IT unboxing it.</summary>
  </entry>
  <entry>
    <title>Live Sound: Mixers, Stageboxes and PA Systems</title>
    <link href="https://punit.co.uk/live-sound/"/>
    <id>https://punit.co.uk/live-sound/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Audio visual"/>
    <summary>A live sound system follows one chain. A source makes sound, a microphone or DI (direct injection) box turns it into a signal, the mixer shapes and routes it, and amplifiers drive the loudspeakers. On the way the signal rises from mic level, about minus 60 to minus 40 dBu, to professional line level at +4 dBu, then to speaker level of tens of volts. The gain set at the preamp decides how well every later stage works.</summary>
  </entry>
  <entry>
    <title>Live Streaming, ATEM Switchers, SDI and SRT</title>
    <link href="https://punit.co.uk/live-streaming/"/>
    <id>https://punit.co.uk/live-streaming/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Audio visual"/>
    <summary>A multi camera live stream is a chain: cameras feed a vision switcher, the switcher feeds an encoder, and the encoder sends one stream to a platform that delivers copies to every viewer. Every camera must match the switcher&#x27;s format, such as 1080p50 in the UK. The stream goes out at CBR (constant bitrate) with a 2 second keyframe interval, over a wired line with about one and a half times the stream bitrate in upload.</summary>
  </entry>
  <entry>
    <title>AV over IP, Dante and Meeting Room Design</title>
    <link href="https://punit.co.uk/av-over-ip/"/>
    <id>https://punit.co.uk/av-over-ip/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Audio visual"/>
    <summary>A network for AV (audio visual) over IP needs controlled multicast, QoS (quality of service) that protects the clock and audio, and enough capacity per port. IGMP (Internet Group Management Protocol) snooping, with one querier per VLAN (virtual LAN), keeps each stream on the ports that joined it. Dante audio needs PTP (Precision Time Protocol) clock packets prioritised and Energy Efficient Ethernet turned off. Video ports are sized by codec: 1 gigabit for compressed 4K, 10 gigabit for SDVoE (Software Defined Video over Ethernet).</summary>
  </entry>
  <entry>
    <title>AV Event Workflows: Plan, Run and Deliver</title>
    <link href="https://punit.co.uk/av-event-workflows/"/>
    <id>https://punit.co.uk/av-event-workflows/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Audio visual"/>
    <summary>AV (audio visual) for a live event is mostly planned before the day, starting with a brief and a site survey. These become the papers the crew works from, such as the signal flow diagram, input list, cable schedule, run sheet and risk assessment. Load in follows a fixed order, with power first. On the day a show caller runs every cue from the run sheet. Before leaving the venue, every recording has three copies on two kinds of storage.</summary>
  </entry>
  <entry>
    <title>Video Editing and Post Production Workflow</title>
    <link href="https://punit.co.uk/post-production/"/>
    <id>https://punit.co.uk/post-production/</id>
    <published>2026-10-23T09:00:00Z</published>
    <updated>2026-11-03T09:00:00Z</updated>
    <category term="Audio visual"/>
    <summary>Video post production runs in seven stages: ingest, organise, edit, colour, audio, deliver and archive. Every camera card is copied to two drives with checksum verification before anything is edited. Colour and the final mix come only after the picture is locked, so no work is done twice. The mix is then set to the destination&#x27;s loudness target in LUFS (loudness units relative to full scale), such as −23 LUFS for broadcast or about −14 LUFS for YouTube.</summary>
  </entry>
</feed>